Skip to content

Site & quality

Bathroom fittings: the right height and place for every fixture

Published 25 November 2026

Site & quality guide from the BHK99 knowledge centre
Site & quality guide from the BHK99 knowledge centre

Fix the heights before tiling - change them later and the tile breaks. The common heights for basin, mixer, shower and geyser, the wet-dry split of a bathroom, and why the WC's sealing ring matters more than its brand.

A bathroom is planned twice: once when the pipes go into the wall, and once when the fittings go onto the tile. If the first pass fixes every height correctly, the second is a pleasure; if not, the tile breaks. The heights are not secrets - they are simply decided before tiling, marked on the wall, and respected.

The common figures: wash basin rim about 800 mm from the floor, mixer or tap outlets about 1.0 m, shower head about 2.0-2.1 m, geyser about 1.8-2.0 m. Keep the shower zone on its own slope as the wet area, with the WC and basin in the dry zone.

Two mistakes that cannot be fixed later

  • An outlet crooked or sunk too deep: after tiling, the mixer will not seat - extensions, gaps and leaks follow. Set outlets dead level with a plug fitted, allowing for the tile thickness so they finish just proud of the tile face.
  • A WC with no sealing: an unfilled gap under the WC leaks and smells from day one. Use a seal ring at the outlet, full bedding below, and silicone around the base.

The right sequence, in six steps

  • Mark the height of every fitting on the wall before tiling.
  • Set mixer and tap outlets level, with plugs fitted.
  • Place the WC's drain and flush connections at the right distance.
  • Provide hot and cold outlets plus an earthed power point at the geyser.
  • Fit the actual fittings only after tiling is complete.
  • Finish with silicone at the basin, the WC and the corners.

Numbers worth remembering

  • Wash basin rim: about 800 mm
  • Mixer / tap: about 1.0 m
  • Shower head: about 2.0-2.1 m
  • Geyser: about 1.8-2.0 m, on an earthed point
  • WC drain: 100 mm (IS 1742)

Site checklist

  • Every outlet height marked and level; tile thickness accounted for
  • Earthing at the geyser point
  • Seal ring and bedding under the WC; silicone at the corners
  • Fittings mounted only after tiling

This guide is adapted from BHK99's illustrated site handbook series. The waterproofing below these fittings is covered in bathroom waterproofing, and the tile they sit on in wall tiles done straight.

Project Enquiry

Tell us about your construction requirements and our team will get in touch.

Our Locations

We serve key locations with a local, on-ground approach.