Skip to content

Site & quality

Bathroom waterproofing: coating, pipe collars and the ponding test

Published 25 November 2026

Site & quality guide from the BHK99 knowledge centre
Site & quality guide from the BHK99 knowledge centre

The ceiling of the room below stays dry only if the bathroom floor holds water back. Rounded fillets at corners, coating carried up the wall, a collar at every pipe - and no tiling until the floor has passed a full ponding test.

Every damp patch on a bedroom ceiling started life as a shortcut in the bathroom above. A bathroom floor is a stack of layers - slab, waterproof coating carried up the walls, filling, sloped screed, then tile - and the coating layer is the one that decides whether the room below stays dry.

Two details carry most of the protection. The coating must climb the wall: at least 300 mm all around, and 1.8-2 m in the shower area. And every corner where floor meets wall gets a rounded cement fillet first, so the coating bends over a curve instead of tearing in a sharp angle.

Two mistakes that cannot be fixed later

  • A broken or missing coating at corners and pipes: water finds the one gap and drips through the slab. Floor and wall must be coated as one piece over rounded fillets.
  • A gap around the pipe: most bathroom leaks start exactly where a pipe passes through the slab. Fill the joint with non-shrink grout and seal over it with a coating-and-fabric collar.

The right sequence, in six steps

  • Clean the floor and walls, remove loose mortar, fix the pipes in place.
  • Make fillets at the corners; grout every pipe penetration.
  • Apply the coating in two coats, crossed over each other, 300 mm up the wall.
  • Block the drain and pond water for 24-48 hours; inspect the ceiling below.
  • Only after a pass: light filling, then a screed sloped about 1:100 to the drain.
  • Tile and grout without damaging the coating.

Numbers worth remembering

  • Coating up the wall: at least 300 mm; shower zone 1.8 m or more
  • Coats: at least 2, applied crosswise, per the manufacturer
  • Ponding test: 24-48 hours with the drain blocked
  • Floor slope: about 1:100 towards the drain
  • Sunken depth: as per the drawing

Site checklist

  • Surface clean; fillets at every corner; every pipe joint sealed
  • Two coats, carried 300 mm up the wall
  • Ponding test passed and recorded before any tiling
  • Screed sloped to the drain

No tiling without a ponding test - one day of checking buys years of peace. This guide is adapted from BHK99's illustrated site handbook series. The same thinking applies overhead: read terrace waterproofing, and for fixture positions see bathroom fittings heights.

Project Enquiry

Tell us about your construction requirements and our team will get in touch.

Our Locations

We serve key locations with a local, on-ground approach.