Published 25 November 2026

Site & quality guide from the BHK99 knowledge centre
Site & quality guide from the BHK99 knowledge centre

Keep clean water covered, give dirty water a path - and never let the two meet. Sump and tank done right, mesh on every overflow, and the inspection chambers that turn a future blockage from digging into a five-minute lid-lift.

Outside the walls, a house runs on two separate water systems: the clean one - sump, pump and overhead tank - and the dirty one - drain pipes falling to inspection chambers and on to the outside drain. The rule that governs both is simple: keep clean water covered, give dirty water a path, and never let the two meet.

On the clean side, the enemies are sunlight, insects and neglect: a tight lid, mesh on the overflow and vent, and cleaning once or twice a year keep the tank water drinkable. On the dirty side, the enemy is the blockage you cannot reach - which is why an inspection chamber belongs at every bend, every junction, and roughly every 30 m of run (IS 1742).

Two mistakes that cannot be fixed later

  • An open tank with no mesh: leaves, insects and mosquitoes join your water supply. Fit a tight lid, mesh the overflow and vent, and provide ladder access for cleaning.
  • A straight buried pipe with no chamber: the first serious choke means digging up the floor. Build a chamber at each bend and junction, with sloped benching inside and a sound lid.

The right sequence, in six steps

  • Fix the sump and chamber positions on the drawing.
  • Build the sump in RCC or waterproofed masonry, its lid above ground level.
  • Set the overhead tank on a strong, level base.
  • Mesh the overflow and vent pipes, facing outward.
  • Build a chamber at every bend, benched inside.
  • Fit all lids and run water through to test.

Numbers worth remembering

  • Chamber spacing: every bend and junction, and within about 30 m (IS 1742)
  • Sump: about 1-2 days of the family's need
  • Lids: tight, and above ground level
  • Tank cleaning: 1-2 times a year
  • Overflow: always meshed (NBC Part 9)

Site checklist

  • Sump waterproof, covered, and away from any waste line
  • Tank level on its base; mesh on overflow and vent
  • A chamber at every bend, benching inside, all lids tight

This guide is adapted from BHK99's illustrated site handbook series. The supply side continues in your home's water layout, and the waste side in drainage, traps and vents.