The pipe hides inside the wall - the plan must never be hidden. How water travels from sump to tank to tap, the 135-litre rule for tank sizing, separate hot and cold lines, and the one habit that saves every future repair: a valve on every branch.
Water reaches your taps by a simple route - sump below, pump beside it, overhead tank on the roof, and gravity down to every outlet - but the difference between a house that is easy to live in and one that fights you for decades is whether that route was planned on paper before a single wall was chased.
Two planning rules do most of the work. First, size the storage: an Indian home is planned at about 135 litres per person per day (IS 1172), and the overhead tank typically holds about a day's need. Second, give every bathroom and the kitchen its own isolation valve - so one dripping tap never again means shutting down the whole house.
Two mistakes that cannot be fixed later
- One valve for the whole house: every small repair becomes a full shutdown. Place a valve on each bathroom and kitchen branch, near the door and within reach.
- A line laid with no plan: a few years later nobody knows where the pipe runs, and one nail finds it. Draw the layout, and photograph every line before it is plastered over.
The right sequence, in six steps
- Mark every tap, shower and geyser position on a drawing first.
- Build the sump below with a pump beside it, piped at the right size.
- Set the overhead tank well above the highest tap.
- Run the main riser down from the tank with a branch at each floor.
- Fit an isolation valve on every bathroom and kitchen branch.
- Run a separate CPVC line for hot water from the geyser, kept apart from the cold line.
Numbers worth remembering
- Water need: about 135 litres per person per day (IS 1172)
- Overhead tank: about one day's need (IS 1172 / NBC)
- Tank height: about 1.5-2 m above the highest tap
- Hot water line: CPVC, or per the manufacturer (IS 15778)
- Isolation valves: every bathroom and the kitchen (NBC Part 9)
Site checklist
- A drawing exists for the whole line; every outlet marked
- Tank sized for the family; a separate valve per bathroom
- Hot and cold lines kept apart; valves reachable, not buried
- Photographs taken before plastering
The pipe hides inside the wall - the plan must never be hidden. This guide is adapted from BHK99's illustrated site handbook series. Choose the pipe itself in CPVC, UPVC, PPR or SWR, and see the concealment rules in chasing and pressure testing.